Home > UNIVERSAL PARTS > POWERED TABLES > Technical Support > Two Leg, Two Motor Support > Version 101 > Screen Reads CAL
Your Screen Reads "CAL"

1. This is generally due to one of three things;

a. The table has just been installed. You must Calibrate (CAL) or sync the legs prior to installation. Failure to do so can result in damage to the table.
b. The table has been moved or reassembled. Again, the table needs to be calibrated prior to use.
c. Sometimes a power outage or severe storm can cause a reset in the memory and set the table to the "CAL" mode. Again, it just needs to be recalibrated.

2. NOTE: Prior to recalibrating this table, make sure you remove all items below the table that could either tip or stop the table from going all the way down. During the "CAL" recalibration mode, the table needs to go down to 23" off the floor. If you do not properly prepare to allow the table to go down, it could result in damage to the product, damage to other items in the way or result in personal injury.

3. Process to recalibrate "CAL" the table.
(Please make sure you follow item #2 and remove any items from under the table).
Again, the table will go down to 23" in height off the floor.

1. CLICK or Press and release the "M" Button (Click)The screen should flash in response
2. Press and hold the 4 button until the table starts to move.
RELEASE THE BUTTON ONCE THE TABLE IS MOVING.
The table will move to the bottom and once it reaches the lowest point, it should rebound very gently and then read "SUC" for success.
3. Once the table reads "SUC" success, it is ready to operate. Press and hold the up arrow for a couple of seconds to restart the table. It should be operating normally at this point.
You should be able to operate the table in
normal conditions now.