44"-72"-Wide Adjustable Height Desk Frame 3-Stage/2-Motor, BlackPowered Table Base designed for use with 44-72” overall tops
Two Motor, Three Stage Unit
Powder coat finish
Finish BU-Black Umber
Control Box with RJ 45 and Molex plug connections, up and down 4 button control with settings.
PLEASE NOTE: PRICING IS FOR FRAME AND CONTROL UNIT ONLY, IT DOES NOT INCLUDE THE TOP
Initial Sync for Omnimax Powered Sit Stand Table OMUJ
SPECIFICATIONS: |
|
|
| Motors | Two | Motor Rating
| 5 amp
| Control Box Rating
| 3 amp
| Control Box Power Draw
| 1.67 amp @ 120v AC
| Control Box Wattage
| 200W | Noise Level | Below 50Db | Stages | Three | Top Width | Adjustable 44-72" | Top Arm Depth | 22 13/16" | Base Construction | Bar, Flat and Tube Steel | Frame Construction | Tube Steel | Finish | Black Powder Coat |
|
| Base Length | 23 5/8" | Base Width | 3 1/2" |
|
| Shortest Width | 44" | Longest Width | 70" |
|
| Range of Height | 23 1/2" - 46 1/4" top of frame | Tested to | BIFMA / ANSI and UL E493537 Test Date August 2017
| Warranty (Limited see specification sheet) | 5 Year on frame 2 Year on motor and control box
|
|
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Features
-
 Powered Table Controller Setup Instructions (For Handset Controls and Error code see below)
Please assemble the unit and follow the instructions below for proper initialization. a) Ensure that all leg cables are connected to the control box. b) Ensure the handset is connected to the control box. c) Plug the power cord into control box and a wall outlet (the table is designed for US 110/120 Volt 3 amp operation) d) To calibrate the table, press the M button, then press the 4 button until the desk starts to lower release and allow to go to minimum height. e) You may notice a slight bounce as the leg syncs and stops. Both legs are at the lowest position. WARNING*******
This Setup must be done prior to operating the table, this sync's the table base with the controller for proper use.
| For Initial Setup and Manual Reset
| A. Press The M Button once, the display will flash (Note there is a YouTube Video showing this setup)
| B. Press the 4 Button and hold, when the leg begins to move release and allow the table to reache the lowest point (23.6)
| C. Once the legs reach the lowest point, you may see a slight bounce in the table, the reading should then show SUC for Success !
| Your desk is now ready to use. Press and Hold the UP Arrow until the unit begins to move, set to desired height.
|
Store a memory position :
The four small buttons with numbers 1, 2, 3, 4 are used to store up to four storage heights.
Step 1: Raise or lower the desk to the height you want to store Step 2: Press M button, the display will flash. Step 3: Press one of numbers button 1, 2, 3 or 4 and the position will be stored at this button.
Error Codes & Notes:
a) E01 or E02
Please stop the unit and check that the wires are properly connected.
b) E04, E05, E07
Please stop the unit and check the wires are properly connected or reduce the load ( weight). Please check wire connection and remove all the loads, then follow these steps if an unknown error code or strange behavior occurs:
Step 1: Press M button, and then press DOWN button. Step 2: Please do nothing until the desk reaches the lowest height and a slight rebound occurs and stops. Step 3: If the desk still doesn’t work after Step 1 and 2, unplug the power, wait a minute, re-plug and repeat 1 and 2 again.
c) H01, DO NOT OPERATE the unit for more than 2 minutes at a time.
Constant use may cause the motor to overheat or temporarily stop working. This will cause a self-protection thermal circuit (H01) to engage. If this happens, wait for 18 minutes and allow motor to reset.
If still doesn’t work properly, please unplug the unit and wait two minutes before replugging the power in. The settings should be restored to normal.
Make sure the desk is reset to the lowest position (You may need to go through the manual reset described above to recalibrate the unit). ___________________________________________________________________________________________________________________________________________- HANDSET MANUAL AND CODE SETTINGS

Normal (standard) mode:
KEY | ACTION | DESCRIPTION | UP
| Press and hold
| The desktop will move upward until you release the key
| DOWN
| Press and hold | The desktop will move downward until you release the key
| M
| Press
| Memory Key, switch between normal and store mode
| M
| Press for 3 seconds
| Lock or Unlock Child Safety Lock
| M + Number
| Press
| Set Memory at current height, choose number postion
| 1
| Press
| Desktop will move to memory setting #1
| 2
| Press
| Desktop will move to memory setting #2
| 3
| Press
| Desktop will move to memory setting #3
| 4
| Press
| Desktop will move to memory setting #4
|
- Store Mode: (Press M Key to switch to store mode)
KEY | ACTION | Description | Up | Press | Saves current position as highest limit | Down | Press | Saves current position as lowest limit | 1 | Press | Saves current position as #1 | 2 | Press | Saves current position as #2 | 3 | Press | Saves current position as #3 | 4 | Press | Saves current position as #4 | M | Press | Cancels Memory Store and Returns to Normal Mode | 3 | Press for 3 seconds | Changes unit of height between inches and cm | 4 | Press for 3 seconds | Calibration and move to minimum height |
Sleep Mode:
The unit will go into sleep mode if left for 1 minute. Press any key to wake up the unit.
Locked Mode:
Pressing and holding the "M" Key for 3 seconds can lock or unlock the Child Safety Feature
In Lock mode, press any key except the "M" key. The display will then show "LOC" in 5 seconds. Display will flash and show height. Press the "M" Key for 3 seconds the display will then show "UNL" for unlock position.
ERROR CODES:
| | | | - Unit needs calibration and reset (see above)
| | | - Stop all legs and check wire connections to leg motor #1
| | | - Stop all legs and check wire connections to leg motor #2
| | | - Stop all legs and check wire connections to leg motor #3 (If supplied with 3rd leg unit (120 and 90 degree units)
| | | - Remove load from leg motor #1
| | | - Remove load from leg motor #2
| | | - Remove load from leg motor #3 (If supplied with 3rd leg unit (120 and 90 degree units)
| | | - Stop all legs check wire connections and/or remove load from desktop
| | | - Stop all legs a count down display will flash intermittently, wait 18 minutes, once the cycle is complete, leg height will display.
| | | - Calibration Success and table is at lowest height. Press and hold up arrow to start table.
| | - Set low or high limit calibration
| - Calibration Success at Manual low or high limit settings. (Custom application using Manual height settings)
| | | - Cancel low or high limit settings
| | - Failure on low or high limit
| - Low or high limit setting failed, reset.
| | | - Child safety lock is on. See lock setting instructions to unlock
| | | - Cancel Child safety lock. See lock setting instructions to unlock
|
|
|
 |
 |
 |
 |

|